Diaphragm Pump Maintenance
The most common cause of operational problems in a silage additive pump is not wear, but inadequate cleaning. Different chemicals may have different effects on the system, but the recommended preventive measure* is the same for all of them:
Run the pump and flush the entire system with lukewarm water after each harvest and again at the end of the season.
This simple maintenance procedure helps prevent deposits, corrosion, and component blockage, ensuring reliable operation and extending the service life of the pump and associated components.
Xtrasil / Kofasil N-LP or N-Ultra
- Products containing salts can lead to crystallisation and deposit build-up.
- These deposits can cause the valves to stick and may act like "sandpaper", increasing wear on the valves and other pump components.
Ensil 1 or Plus
- Pure acid solutions that do not contain sugars or salts generally do not cause valve sticking, crystallisation, or deposits.
- However, these products contain stronger acids than those mentioned above, which may contribute to corrosion and component wear over time.
IMPORTANT
- Regular cleaning of filters, the pump, and nozzles, combined with routine functional inspections, helps ensure reliable operation and extends the service life of the equipment.
- To minimise maintenance issues, always flush the system thoroughly with clean, lukewarm water after each harvest and at the end of the season.
AFTER EACH HARVEST:
1. Place the suction tube in a clean bucket of lukewarm water.
2. Run the pump and flush the system until clean water is discharged from the nozzles.
This procedure ensures effective cleaning of the filter, flow meter, pump, hoses, and nozzles. Regular flushing reduces the risk of valve sticking, crystallization, deposit build-up, corrosion, and unnecessary wear, helping to ensure reliable operation and extend the service life of the equipment.
AT THE END OF THE SEASON:
Step 1 – Cleaning
Run the pump and thoroughly flush the entire system with lukewarm water.
Remove and clean the filter thoroughly.
Step 2 – Winterisation (for Winter Storage)
Run a mixture of 50% antifreeze and 50% water through the entire system to protect all components from freezing.
This mixture should be circulated through the pump, flow meter, hoses, and nozzles to ensure complete frost protection.
Step 3 – Lubrication
Apply a light coating of silicone grease to the O-rings, quick couplings, and electrical connectors.
Important
Following this end-of-season maintenance procedure helps prevent freeze damage, corrosion, sticking valves, and premature component wear. Proper cleaning, winterisation, and lubrication will contribute to reliable operation and extend the service life of the entire system.
IMPORTANT!
Do not use oil-based lubricants, such as WD-40, for lubrication. These products can cause the O-rings to swell, deteriorate, and eventually fail.
Always use silicone grease or another lubricant specifically recommended for rubber seals and O-rings. This will help maintain proper sealing performance and extend the service life of the components.
Step 4 – Storage
Store the Display and pump unit in a clean, dry, and frost-free location, protected from direct sunlight.
Proper storage helps prevent moisture damage, corrosion, UV degradation, and damage caused by freezing temperatures, ensuring the equipment is ready for reliable operation at the start of the next season.